Sun Fire V240 RAM Replacement

From Brandonhutchinson.com

Revision as of 18:26, 9 November 2007 by Hutch (Talk | contribs)
(diff) ←Older revision | Current revision (diff) | Newer revision→ (diff)
Jump to: navigation, search


Messages during POST:

0>Test Memory....|
0>ERROR: TEST = Address Bitwalk on Slave 1
0>H/W under test = MB/P1/B1/D1 (Bank 2), Motherboard
0>Repair Instructions: Replace items in order listed by 'H/W under test' above.
0>MSG = Pin 175 failed on MB/P1/B1/D1 (Bank 2), Motherboard
0>END_ERROR
...
0>ERROR:
0>      POST toplevel status has the following failures:
0>              MB/P1/B1/D1 (Bank 2), Motherboard
0>END_ERROR
...
Power On Selftest Failed.
   CPU: 0 cause: MB/P1/B1/D1 (Bank 2), Motherboard
   CPU: 1 cause: MB/P1/B1/D1 (Bank 2), Motherboard
NOTICE: CPU 1 has 2048/4096 MB of memory disabled

ERROR: The following devices are disabled:
    dimm7


ERROR: POST failed
                                                                      
SC Alert: MB/P1/B1/D1 (Bank 2), Motherboard has been failed by POST

SC Alert: MB/P1/B1/D1 (Bank 2), Motherboard